Canon imagePRESS C1 Service Manual - page 548
Chapter 9
9-11
9.2.2 Print (Constant Speed)
0012-0965
imagePRESS C1 P / imagePRESS C1 / imagePRESS C1+ (Printer) / imagePRESS C1+
- In the case of plain paper (=/
F-9-11
*1: H3 and H4 turn ON in alternate shifts
*2: In the black-and-white mode/overseas models, temperature is controlled according to the temperature detected by the main thermistor (THM1) and sub ther-
mistor (THM2). As for black-and-white/Japanese models, temperature is controlled by the main heater.
*3: Fixing web solenoid is turned ON once for each small paper, and twice for each paper larger than that.
*4: 1/3-speed rotation
*5: Constant speed rotation
*6: Only when the temperature of the inlet roller main thermistor (THM3) is detected as 100 deg C or more.
Interval
Description
STBY (standby)
Ready for a print request signal
fixing roller surface temperature = 165 deg C/outside heating roller surface temperature = 200 deg C/fixing belt surface
temperature = 95 deg C
INTR (initial rotation)
Time from receipt of the print request signal to sending image signal
PRINT (print)
Time from the print start to delivery of paper. Control temperature varies according to the color mode.
Full color: Fixing roller surface temperature = 155 deg C/ Outside heating roller surface temperature =200 deg C / Fixing belt
surface temperature = 95 deg C
Black-and-white: Fixing roller surface temperature = 160 deg C / Outside heating roller surface temperature =200 deg C / Fixing
belt surface temperature = 95 deg C
LSTR1(last rotation 1)
In the case the fixing belt surface temperature reaches =/> 95 deg C
LSTR2(last rotation 2)
In the case the fixing belt surface temperature reaches =/> 160 deg C
LSTR3(last rotation 3)
In the case the fixing roller surface temperature =/> 155 deg C /outside heating roller surface temperature =/> 200 deg C /fixing
belt surface temperature =/> 90 deg C
Fixing main heater
(H1)
Fixing sub heater
(H2)
Outside heater
(H4)
Inlet heater
(H3)
Fixing motor
(M38)
Fixing belt attach/detach
motor (M34)
Outside heating
attach/detach motor (M45)
Fixing web attach/
detach motor(M33)
Fixing belt drive motor
(M36)
Fixing web solenoid
(SL11)
Fixing belt cooling fan
1
4 (FM11
14)
STBY
INTR
LSTR2
LSTR3
STBY
LSTR1
detachment->
detachment->
detachment->
attachment
detachment
detachment
detachment
attachment
attachment
3
3
6
6
1
2
2
1
1
4
4
5