Canon imagePRESS C1 Service Manual - page 1160
Chapter 16
16-263
CARD-RNG
Set the number of cards available.
Set the number of cards available when using a card reader.
2
Setting range: 1 to 1000
Standard value: 1000
[Reference]
In the current condition, the starting number of the card is specified by COPIER > FUNCTION >
INSTALL > CARD, and the fixed number of cards is specified starting from that number. (ex.
fixed at 1000 cards)
WUEN-LIV
Set the activation interval after a sleep notice was provided from network.
Set the interval from when sleep activation was performed to the copier main unit from network
without sending a job to when the machine enters the sleep mode next.
2
Setting range: 10 to 600
Standard value: 15
(Unit: second) *10 seconds to 10 minutes
COMP-PRT
When performing printing for "printing of a page number / printing of the number of copies /
printing of a date / bookbinding / printing of a tint block (hereinafter called 'combined printing')
with the copying number of 2 or more, printing is prioritized in memory allocation for image
processing for a certain memory model (option) or document size. This causes a lack of memory
for image processing of scanning, SEND transmission (excluding FAX), and PDL input
operation, and such operation cannot be performed until printing is completed.
This mode is used to perform equal memory allocation to all jobs so that operation such as
scanning, SEND transmission (excluding FAX), and PDL input can be performed before printing
is completed (so that such operation is performed little by little).
2
Setting range
0: Prioritize printing.
1: Perform equal memory allocation.
Standard value: 0
SHT-DCSW
Skip the DCON termination processing when executing shutdown.
2
Setting range
0: Execute shutdown after the DCON fan control is terminated.
1: Execute shutdown before the DCON fan control is terminated.
Standard value: 0
ADJ-VPP
Adjust the developing bias Vpp.
Function to adjust Vpp for the developing AC bias.
2
Setting range: -4 to 2
Standard value: 0
AST-SEL
Change the range of the advanced smoothing.
AST-SEL (AST level SELect)
2
Setting range: 0 to 3
Standard value: 2
REGM-SEL
Change the range of the thin line density correction.
REGM-SEL (REos GaMma SELect)
2
Setting range: 0 to 4
Standard value: 2
ADJ-BLNK
Adjust the length of the developing bias blank.
Function to adjust the blank length of the developing bank pulse bias
2
Setting range: 1 to 4
Standard value: 3
2TR-RVON
Set ON/OFF of the weak bias of the trail edge of paper.
Set this mode to ON when scattering occurred to the trail edge of the image on the 2nd side in 1/
3 speed.
2
Setting range
0: OFF
1: ON
Standard value: 0
USB-RCNT
Auto-connection setting at disconnection of USB device (USB RECONNECT)
2
Setting range: 0 to 1
0: Non auto-connect
1: Auto-connect
Standard value: 0
FAN-TM1
Operation time change of fans for primary charging series
Change the operation time of fans for primary charging series at last rotation.
2
Setting range: 0 to 55 (1 scale: 1 min)
Standard value: 55
Supplement: This service mode applies to the following three fans.
- Primary exhaust fan (FM2)
- Left exhaust fan (FM16)
- Primary exhaust assist fan (FM18)
Make sure to set the setting value to 15 min or more.
This item applies to the upgraded device (DCON Ver11.03 or later, Cont Ver24.04 or later)
DMX-OF-Y/M/C/K
Change of the Dmax setting (Y/M/C/K)
2
Setting range: -3 to +3
Amount of the change for 1 increment: 0.07%
When the density is low, increase the value, and then execute automatic gradation correction.
ACR-LV-K
Setting of the timing of ACR (Auto Carrier Refresh) in single black mode
2
Setting range: -4 to +2
Standard value: 0
COPIER > OPTION > BODY
Subheading Contents
Level