Canon imagePRESS C1 Service Manual - page 937
Chapter 16
16-40
6.ERR
F-16-19
-
1 to 50 (The larger the number is, the older the error is.)
-
-
-
- Error code
-
-
T-16-52
-
Not used
7.HV-STS
T-16-53
0045
feed sensor
PI8
1st; not reaching the read sensor
0046
feed sensor
PI8
1st; stationary at the read sensor
0047
delivery reversal sensor
PI9
1st; not reaching heat delivery sensor
0048
delivery reversal sensor
PI9
1st; stationary sensor at the delivery sensor
0071
wrong timing
-
error software timing
0073
wrong timing
-
the shift motor is faulty
0090
ADF open/closed sensor 1
PS502
the ADF is opened during operation
0091
ADF open/closed sensor 1
PS502
the ADF is opened during operation (while paper is in wait)
0092
DF cover open/closed sensor
PI6
A cover is opened during operation (while a drive mechanism is in operation).
0093
DF cover pen/closed sensor
PI6
A cover is opened during operation (in wait for paper).
0094
registration sensor, separation
sensor, feed sensor, delivery
reversal sensor
PI1,PI7,PI8,PI9 Paper is detected in the path while the 1st sheet is being picked up.
0095
original placement sensor, DF
cover open/closed sensor, ADF
open/closed sensor 1
PI5,PI6,PS502
A signal arrives indicating the start of pickup in the absence of an original in the tray or while
the machine is in an OPEN state.
Location Classification
0
main controller
1
Feeder
2
finisher
3
not used
4
reader unit
5
printer unit
6
PDL board (any of)
7
fax board
COPIER > DISPLAY > HV-STS
Subheading
Contents
Level
PRI-GRID
Grid voltage of the primary charging assembly (Unit: V)
1
PRE-TR
Current level of the pre-transfer charging assembly (Unit: µA)
1
BIAS
DC value of each color developing bias (Unit: V)
1
1TR-CMOF
Offset for adjustment of the primary transfer DC current monitor
Setting range: -999 to 999(mv)
1
Code
Sensor type
Sensor notation
Description