Canon imagePRESS C1 Service Manual - page 1245
Chapter 17
17-20
F-17-39
17.5 Uploading and Downloading Backup Data
17.5.1 Outline
0013-8282
imagePRESS C1 P / imagePRESS C1 / imagePRESS C1+ (Printer) / imagePRESS C1+
The file MeapBack is a MEAP application and its data stored on the HDD.
The file SramDCON is data stored in the SRAM of the DC controller PCB.
The file SramRCON is data stored in the EEPROM of the reader controller PCB.
T-17-4
Points to Note When Uploading/Downloading MeapBack
If you need to re-install the system software to correct a fault, you may upload MeapBack and then download it back after formatting the HDD (by temporarily
putting aside the MEAP application).
1) Upload MeapBack.
2) Execute HDD all format.
3) Re-install the system software.
At this time, be sure that the system software is the same as that existed before formatting the HDD. Otherwise, you will not be able to download MeapBack
you have uploaded.
4) Download MeapBack.
You will not be able to download MeapBack you have uploaded unless you are downloading it to the machine you have uploaded it from.
MEMO:
- If you are planning to replace the HDD or execute ALL or APL_MEAP formatting, it will be a good idea to upload the MeapBack file in advance and then
download after the work by way of temporarily keeping away the MEAP application.
- If you are planning to replace the Reader controller PCB, you can upload the SramRCON file in advance, and download it after replacement so that the service
mode and other settings may be inherited.
- If you are planning to replace the DC controller PCB, you can upload the SramDCON file in advance, and download it after replacement so that the service mode
and other settings may be inherited.
17.5.2 Uploading Procedure
0013-8283
imagePRESS C1 P / imagePRESS C1 / imagePRESS C1+ (Printer) / imagePRESS C1+
- When uploading the data, do not select 'SramImg.bin' or 'Sublog.txt'.
- The machine must be in normal mode for uploading/downloading SramDCON or SramRCON.
- The machine must be in safe mode when uploading/downloading MeapBack.
[In the Case of MeapBack]
1) Start up the SST.
2) Select the model [1] and the type of system software [2] ('Single'); then, check the network settings, and click [START].
Backup data
File to select for downloading
For R&D
SramImg.bin (do not select this file)
MEAP application
MeapBack.bin (may be uploaded/downloaded in safe mode)
For R&D
Sublog.txt (do not select this file)
Reader controller PCB backup
SramRCON (may be uploaded/downloaded in normal mode)
DC controller PCB backup
SramDCON (may be uploaded/downloaded in normal mode)
SelectableFirmware
SelectableFirmware
Control
172.16.1.100
iPR_C1
NORMAL
SYSTEM
Firmware Version
Active
USenXXXXn
Hold
USenXXXXi
RCON
XXxxXXXX
DCON
XXxxXXXX
MEAPCONT
XXxxXXXX
BOOTROM
XXxxXXXXC
RUI
XXjaXXXX
XXenXXXX
LANGUAGE
XXjaXXXX
XXenXXXX
C l i c k t h e b u t t o n o f t h e t a s k t o b e
exe c u t e d .
S e l e c t t h e f i r m w a r e t o b e
d o w n l o a d e d . t h e n c l i c k t h e [ S t a r t ]
b u t t o n .
ServiceSupportTool DLM10 (Ver.3.22E)
C l e a r
Shutdown
Retur n to Main Menu
Star t
U p l o a d D a t a
D ow n l o a d D a t a
R e s t o r e B a ck u p S y s t e m
Fo r m a t H D D
D ow n l o a d F i r m wa r e
[1]
BOOT
iPR_C1
BROWSER
DCON
HDFormat
iRCXXXX
KEY
G3FAX
HELP
LANGUAGE
MEAPCONT
MEDIA
RCON
RUI
TTS
WebDAV
SYSTEM
TSTMP