Canon imagePRESS C1 Service Manual - page 1150
Chapter 16
16-253
AUTO-DH
Set the permission/prohibition to automatically start the automatic gradation control which is
executed when the machine is left for a specified period time or the environment changes in the
ON/OFF standby condition for automatic gradation correction control.
The setting value becomes valid after the main power switch is turned OFF/ON.
1
Setting range
0: Prohibited
1: Permitted (default)
Standard value: 1
DFDST-L1
Adjust the dust detection level for DF (between-sheet correction)
Increase the setting value to increase the dust detection level. (It becomes easier to detect dust
which causes a thin line.)
1
Setting range: 0 to 255
Standard value: 93
DFDST-L2
Adjust the dust detection level for DF (detection after job)
Increase the setting value to increase the dust detection level. (It becomes easier to detect dust
which causes a thin line.)
1
Setting range: 0 to 255
Standard value: 80
ENVP-INT
Set the log acquisition interval for temperature/humidity in the machine and fixing temperature.
Set the log acquisition interval for COPIER > FUNCTION > MISC-P > ENV-PRT and COPIER
> DISPLAY > ENVRNT.
1
Setting range: 0 to 480 (minute)
Standard value: 60
Reference
Log acquisition not implemented at 0 minute.
T1-TEMP
Switch the down sequence table for thick paper 1.
1
Setting range
0: Default
1: Fixing is prioritized.
2: Productivity is prioritized.
Standard value: 0
The setting value becomes valid after the main power switch is turned OFF/ON.
T2-TEMP
Switch the down sequence table for thick paper 2.
1
Setting range
0: Default
1: Fixing is prioritized.
2: Productivity is prioritized.
Standard value: 0
The setting value becomes valid after the main power switch is turned OFF/ON.
CD-IDL-T
Adjust the time to execute idling at first power-on for the IDL-T color developer (YMC).
Set the time to execute idling at first power-on for the color developer (YMC), which is sometimes
executed by initial multiple rotations under high-humidity environment.
When you decrease the setting value, downtime of initial multiple rotations can be reduced, but
density change from the first power-on is somewhat worsened.
When you increase the setting value, density change from the first power-on is improved, but
downtime of initial multiple rotations increases.
1
Setting range: -3 to +6 (1 level: 5 second)
Standard value: 0
The setting value becomes valid after the main power switch is turned OFF/ON.
CNTR-DSP
Select the screen display according to the external controller.
1
Setting range
0: Display the external controller icon in the control panel of the copier main unit. (setting when
the color image server is connected)
1: Do not display the control panel of the copier main unit. (setting when the external controller
with an control panel is connected)
Standard value: 0
BASE-SW
Make a setting to switch the setting from the MEAP-full model to the Base model.
Make a setting to switch the device which operated as a full model back to the base model.
1
Use it when trouble attributable to MEAP application occurs. By setting to '0', the operation of
MEAP application can be controlled.
settings
0: off (base model); 1: on (full model) [Default]
MEMO:
The change only from '1' to '0' is possible.
COPIER > OPTION > BODY
Subheading Contents
Level