Canon imagePRESS C1 Service Manual - page 547
Chapter 9
9-10
9.2 Basic Sequence
9.2.1 At Power-On
0012-0964
imagePRESS C1 P / imagePRESS C1 / imagePRESS C1+ (Printer) / imagePRESS C1+
In case the surface of the fixing roller is
F-9-10
*1: H3 and H4 turn ON in alternate shifts
*2: 1/3-speed rotation
*3: Goes on every 30 seconds (web take-up).
*4: Only when the temperature of the inlet roller main thermistor (THM3) is detected as 100 deg C or more.
Interval
Description
WMUP1
(warm-up 1)
From when the power is turned on until the fixing roller surface temperature reaches 100 deg C. Thereafter, shifts to WMUP2.
WMUP2
(warm-up 2)
Until the fixing belt surface temperature reaches 100 deg C. Thereafter, shifts to WMUP3.
WMUP3
(warm-up 3)
Unit the fixing roller surface temperature reaches 160 deg C. Thereafter, shifts to WMUP4.
WMUP4
(warm-up 4)
Until the fixing roller surface temperature reaches 160 deg C, the fixing belt surface temperature reaches 190 deg C, and the
outside heating roller surface temperature reaches 90 deg C. Thereafter, shifts to STBY.
STBY(standby)
Ready for a print request signal.
fixing roller surface temperature = 165 deg C/outside heating roller surface temperature = 200 deg C/fixing belt surface
temperature = 95 deg C
3
3
2
1
1
3
4
Fixing main heater (H1)
Fixing sub heater (H2)
Outside heater (H4)
Inlet heater (H3)
Fixing motor (M38)
Fixing belt
attach/detach motor (M34)
Outside heating
attach/detach motor (M45)
Fixing web
attach/detach motor (M33)
Fixing belt drive motor(M36)
Fixing web solenoid (SL11)
Fixing belt cooling fan 1-4
(FM11
14)
WMUP1
Power On
WMUP2
700 sec or less
WMUP3
WMUP4
STBY
detach-
ment->
detach-
ment->
detach-
ment->
detachment->
detachment->
detachment
attachment->
attachment->
detachment->
detachment->
detachment
attachment->
attachment->
detachment->
detachment
attachment-> attachment->
attachment->