Canon imagePRESS C1 Service Manual - page 867
Chapter 15
15-4
E004
Error in protection circuit of fixing assembly
Open circuit/poor contact of main thermistor (THM1, THM3, THM5) or sub thermistor (THM4, THM5, THM6), fault of AC driver PCB or DC
controller, open circuit/poor contact of heater.
0101 Detecting open circuit of the film side of the fixing main
thermistor
Turn off and then on the main power
0102 Detecting short circuit of the film side of the fixing main
thermistor
Turn off and then on the main power
0103 Detecting open circuit of the case side of the fixing main
thermistor
Turn off and then on the main power
0104 Detecting short circuit of the case side of the fixing main
thermistor
Turn off and then on the main power
0010 Open circuit of the fixing roller thermistor
The difference of the detecting temperature between the main
thermistor and the sub thermistor of the fixing roller is 50 deg C or
more, and this state continues for 500 msec
Turn off and then on the main power
0020 Open circuit of the external heat thermistor
The difference of the detecting temperature between the main
thermistor and the sub thermistor of the external heat roller is 50
deg C or more, and this state continues for 500 msec
Turn off and then on the main power
0030 Open circuit of the inlet thermistor:
Turn off and then on the main power
0040 An error to find foreign matter in the fixing main thermistor:
During standby, the difference in detecting temperature between
the main thermistor and the sub thermistor of the fixing roller is 25
deg C or more, and this state continues for 500 msec
Turn off and then on the main power
0000 to 000F There is an open circuit in heater (triac short-circuit error)
The hardware detects the error for 200 msec continuously.
bit 0: external heater SSR error
bit 1: fixing sub heater SSE error
bit 2: fixing main heater SSR error
bit 3: inlet heater SSR error
Turn off and then on the main power
E005
There is an error in the take-up mechanism of the web
0000 Error in absence of the fixing web: after the fixing web level
sensor has detected the absence of the web, the count exceeded
3000.
Reset in service mode: COPIER>FUNCTION>CLEAR>ERR
If you have replaced the web, reset the reading in the followings,
and turn off and then on the power: and
COPIER>COUNTER>DRBL-1>FX_WEB
0001 Open circuit error of the fixing web drive solenoid
Reset in service mode: COPIER>FUNCTION>CLEAR>ERR
E006
Error in connection of fixing unit
0000 Fixing drawer connect error (hardware detection)
With the front door closed, fixing unit uninstalled status is
detected.
l Check the connection of fixing assembly.
0001 Error in connection of fixing unit (software detection)
At sleep or energy saving mode, unmounted fixing unit was
detected for continuous 500 msec or more with the front cover
closed.
1.Check to see that the lever of the fixing/feed assembly has been
correctly set.
2.Check the connection of the fixing driver PCB
3.Check the connection of the DC controller
0002 Error in connection of fixing unit (hardware detection)
At normal copy, unmounted fixing unit was detected for one
moment (0.6 msec) with the front cover closed.
1.Check to see that the lever of the fixing/feed assembly has been
correctly set.
2.Check the connection of the DC controller.
E007
Belt displacement error
0001 Front side belt displacement error
After placing the fixing belt position to the center, turn off and
then on the power
0002 Rear side belt displacement error
After placing the fixing belt position to the center, turn off and
then on the power.
0003 Fixing belt displacement error
The belt is fully displaced at power-ON/The belt cannot recover
from the belt displacement.
Measurement setting for when E007 error occurs in service mode.
Specify “1” in (COPIER>OPTION>BODY>F-BLT-RT) and turn
OFF/ON the power.
0007 Detection of displacement error by the double error detection
After placing the fixing belt position to the center, turn off and
then on the power.
0010 After turning on the steering motor, HP detection fails within 1sec. After placing the fixing belt position to the center, turn off and
then on the power.
0100 HP detection error 1 at initialization
After placing the fixing belt position to the center, turn off and
then on the power.
0200 HP detection error 2 at initialization
After placing the fixing belt position to the center, turn off and
then on the power.
E008
There is an error in relation to the life of the fixing assembly
0001 In the case that the print count of the fixing roller exceeds specified
count (this error becomes effective when modifying service
settings), the specified count is determined by the following
service mode:
-Alert service mode (FXWRNLVL) 0:180k/1:150k/2:120k
[default 0]
-Error service mode (FXERRLVL) 0:+20k/1:+40k/2:+60/3:
disable error [default 3]
-ON/OFF (FXMSG-SW) of alert display 0: nondisplay/1: display
[default 0]
When you have replaced the fixing roller, reset in service mode,
and turn off and then on the main power:
COPIER>COUNTER>DRBL-1>FX-UP-RL
E009
Error in relation with power supply
0000 Error in power supply of the location
Check the power supply of the location with the DC controller, and
then, insert the connector.
0001 Error in detecting 24V connection of decurler
Check the sub power supply code and the decurler's power supply
Code
Cause (Detection Description)
Remedy