12.3 Scheduled Servicing Basic Procedure
12.3.1 General Procedure for Scheduled Servicing
0012-1982
imagePRESS C1 P / imagePRESS C1 / imagePRESS C1+ (Printer) / imagePRESS C1+
- The scheduled servicing should be basically implemented per 25,000 sheets.
- Check the service book when going for the scheduled servicing. Bring it when the parts replacement may be necessary.
- Connecting the power plug for a long time at the place filled with the dust, moisture and oily smoke may cause a fire (The dust accumulated around there
absorbs the moisture and may cause the poor insulation). The power plug should be regularly unconnected, the dust or dirt accumulated around it/the consent
should be cleaned with a dry cloth.
1.Operation Procedure
1) Greetings to the person in charge: The status confirmation
2) The counter record: Check the misprint
3) Check the following items, clean/adjust each area.
4) Checking the Waste Toner Receptacle
When the waste toner accumulates above the level of half of the receptacle, collect the waste toner in a vinyl bag, etc. Or replace the waste toner receptacle
- When disposing the waste toner, obey the disposal standards of each local government.
- Do not throw the waste toner into the fire (It may explode, very dangerous!)
5) Clean the copyboard glass and reading glass
6) Implement the test copy.
7) Implement the sample copy.
8) Operation check for the leakage breaker
Press the test switch of the leakage breaker at the status of power switch (ON), and check if the leakage breaker normally works (The breaker switch tilts on the
side of OFF to shut the power).
If the leakage breaker does not normally work, replace the leakage breaker and check it again.
2. Recovery Procedure
After checking the operation, turn OFF/ON the main power switch.
1) Organize the sample copies, clean and clear up the surroundings of the machine.
2) Record the last counter. Record also the service counter for COUNTER>DRBL-1 'FX-UP-RL'.
3) Write them in the service book, report them to the person in charge. Write the history of the leakage breaker operation check in the service book.
12.3.2 Scheduled Servicing List Reader Unit
0014-2820
imagePRESS C1 P / imagePRESS C1 / imagePRESS C1+ (Printer) / imagePRESS C1+
Do not use the solvent/oil other than the specified one.
MEMO:
The meanings of marks used in the subsequent chart are as follows.
A: Cleaning B: Replacement C: Lubrication D: Adjustment E: Maintenance
Check items
Test copy
Image density standards
Soiled background
Character definition
Margin
Fixing
Faulty registration, soiled back
Margin specification
(one-sided print)
Leading edge: 4.0+1.5/-1.0mm
Left edge: 2.5+/-1.5mm
(two-sided print)
Leading edge: 4.0+1.5/-1.0mm
Left edge: 2.5+/-2.0mm
Feeding system
Registration upper lower roller
Paper powder at the front of the
registration assembly