Chapter 2
2-61
2) Connect the 2 power plugs (1 for the backside, and 1 for the left side of
the machine) of the machine to different power outlets, and turn on the
main power [1].
F-2-195
2.2.21 Turning the Main Power ON
0012-7226
imagePRESS C1 P / imagePRESS C1
- In case of 100V machine, connect the machine to the ground using the
ground wire.
1) Remove the screw [1] and the toothed washer [2].
F-2-196
2) Putting the ground wire [2] in between, attach the toothed washer [1] re-
moved in the step 1) with the screw [3].
F-2-197
3) There must be a grounding terminal for the machine.
Targets of Grounding
- Grounding terminal of power outlet
- Grounding terminal of which grounding work (D Type) is properly
done.
4) Connect the 2 power plugs (1 for the backside, and 1 for the left side of
the machine) of the machine to different power outlets, and turn on the
main power [1].
F-2-198
Use the correct power code to mach the location/area of installation. Make
sure not to leave unused power code at the site.
Before turning the main power on, be sure to remove the packing materials.
ON
OFF
[1]
[2]
[1]
Do not connect the grounding cord to the gas pipe.
[2]
[2]
[1]
[2]
[3]
100V
2.9A
100V
15A
120V
2.6A
120V
15.1A
230V
1.3A
230V
9.2A
MAIN