Canon imagePRESS C1 Service Manual - page 1149
Chapter 16
16-252
FIX-TEMP
Switch the plain paper down sequence table.
1
Setting range
0: Default
1: Fixing is prioritized
2: Productivity is prioritized
Standard value: 0
The setting value becomes valid after the main power switch is turned OFF/ON.
Usage:
Select '0' when giving preference to the image quality (fixing), '2' when giving preference to the
speed (productivity).
PASCAL
Set if using the contrast electric potential and gradation correction data obtained by automatic
gradation correction (full correction) control, or not.
1
Setting range
0: Use the data.
1: Do not use the data.
2: Reserve (same operation as 1)
3: Reserve (same operation as 0)
Standard value: 1
The setting value becomes valid after the main power switch is turned OFF/ON.
For printer model, be sure to make the setting value 0 at installation.
CONFIG
Select several system software stored in the hard disk, change the nation/area, paper size.
1
Procedure:
1) Select
2) Select the item to change.
3) Press the +/- key. (Each press changes the setting.)
4) Display the contents to be needed, press OK key.
5) Turn off and then back on the main power switch.
XXYYZZAA
XX: country (e.g., JP=Japan)
YY (*): language (e.g., ja=Japanese)
ZZ: (*) destination (e.g., 00=Canon)
AA: paper size series (00=AB; 01=inch; 02=A; 03=inch/AB)
*: Cannot change the setting.
TEMP-TBL
Fixing assembly temperature control
Temperature settings become effective after the main power is switched OFF / ON .
Fixing assembly temperature control
Upon activation of this mode,
Temperature of the following increase by 5 deg C: stand-by temperature (both of the 2 types),
copying temperature, stand-by last rotation temperature, sheet-to-sheet temperature control for
long sheets.
Temperature of the following does not increase by 5 deg C: job last rotation temperature, power
save mode temperature, error detection temperature.
Make adjustments to the setting in the temperature control table.
The setting in the fixing assembly temperature control table is modified when certain properties
of paper used in the field cause blistering of paper or low temperature offset.
Change the setting to "0" when low temperature offset occurs.
Change the setting to "1" when blistering of paper occurs.
1
Setting range
0: OFF (default)
1: - 5 deg C
2: - 10 deg C
3: - 15 deg C
4: - 20 deg C
Standard value: 0
W/SCNR
Set the presence/absence of the reader for the copy model.
1
Setting range
0: Printer model (without a scanner)
1: Model with a scanner
Standard value: 0
The setting value becomes valid after the main power switch is turned OFF/ON.
RUI-DSP
Set the options for the copy function in the RUI screen.
1
Setting range
0: Do not display the copy screen in RUI.
1: Display the copy screen in RUI.
Standard value: 0
INTROT-1
Set the image adjustment control implementation interval at last rotation.
1
Setting range: 0 to 500
Standard value: 60
The setting value becomes valid after the main power switch is turned OFF/ON.
INTROT-2
Process auto-adjustment implemented for every specific number of sheet.
Set the interval (sheets) against the process auto-adjustment.
1
Setting range: 50 to 10000 (small image)
Standard value: 2000
The setting value becomes valid after the main power switch is turned OFF/ON.
INTROT-T
Set the interval time of auto-adjustment control (simple control)
1
Setting range: 50 to 10000 (small image)
Standard value: 400
The setting value becomes valid after the main power switch is turned OFF/ON.
COPIER > OPTION > BODY
Subheading Contents
Level