Canon imagePRESS C1 Service Manual - page 358
Chapter 7
7-9
F-7-9
7.3.2 When Turning the Power ON
0020-4112
imagePRESS C1+ (Printer) / imagePRESS C1+
In case of turning on the main power switch when the temperature of the fixing roller surface is under 50 deg C. (when turning on the main power switch after
leaving it for a long time, e.g., in the morning)
1. Feature
- Right after starting the sequence, execute the HP detection of the developing rotary and eliminate static from the drum surface.
- The approximate time required from turning on the main power switch to being the standby state is about 9min 10sec. (max. time is less than 11min 40sec)
- During the warm-up rotation, the following controls are executed:
Wire cleaning, potential control, primary/secondary transfer ATVC control, ITB cleaner ACVC control, ATR patch control, development idle rotation control,
D-half control *1
*1: Execute the control if there is the history of more than 500 sheets color printing, or when the environment is changed.
F-7-10
7.3.3 Copy / Print (Normal Speed)
0012-6533
imagePRESS C1 P / imagePRESS C1
In case of full color, plain paper, an A4 sheet.
1. Feature
Printer unit
WMUPR
Downstream ITB cleaner bias
high pressure
Secondary transfer outside
roller drive motor
Secondary transfer bias
Secondary transfer cleaning
bias
ITB cleaner contact/separation
motor
ITB cleaner rotation
Primary transfer bias
Tension roller bias
Secondary transfer outside
roller contact/separation motor
Upstream ITB cleaner high
pressure
Drum/ITB motor
Pre-conditioning LED
Primary charging bias
Grid bias
Developing rotary motor
Developing bias (DC)
Developing bias (AC)
Developing clutch
Post charging bias
Main power switch ON
Printer unit
WMUPR
Downstream ITB cleaner bias
high pressure
Secondary transfer outside
roller drive motor
Secondary transfer bias
Secondary transfer cleaning
bias
ITB cleaner contact/separation
motor
ITB cleaner rotation
Primary transfer bias
Tension roller bias
Secondary transfer outside
roller contact/separation motor
Upstream ITB cleaner high
pressure
Drum/ITB motor
Pre-conditioning LED
Primary charging bias
Grid bias
Developing rotary motor
Developing bias (DC)
Developing bias (AC)
Developing clutch
Post charging bias
Main power switch ON