Canon imagePRESS C1 Service Manual - page 925
Chapter 16
16-28
9.DENS
T-16-35
10.MISC
P-LPW-Y/M/C/K
Laser power value of Y/M/C/K color which is a target patch contrast electric potential
0 to FF (Unit: hex only)
2
COPIER>DISPLAY>DENS
Subheading
Contents
Level
DENS-Y/M/C
Calculated value of the developer density (Y/M/C) (The difference to the target value is displayed
in %.)
Reference
The value is updated at the point when toner supply is performed after the main power switch was
turned on.
Correct value: -2.0 to 4.0%
1
REF-Y/M/C
Standard of the developer density on the developing cylinder (Y/M/C)
The value is updated at the point when toner supply is performed after the main power switch was
turned on.
Correct value: 464 to 560
1
SGNL-Y/M/C
Measurement value of the developer density (Y/M/C)
Measurement is performed every time when a job is entered.
Reference
The value is updated at the point when toner supply is performed after the main power switch was
turned on.
Correct value: 250 to 760
1
DENS-S-Y/M/C/K
Detected density value of the sample image created in ATR control (Y/M/C/Bk)
Correct value: 250 to 450
2
D-Y/M/C -TRGT
Target value of the developer density (Y/M/C)
2
P-SENS-P
Detected value of the light volume on the base (drum) in patch detection ATR control
2
DEV-DC-Y/M/C/K
Output value of the target developing DC voltage (Y/M/C/Bk) (Current value)
2
D-CRNT-P/S
Measurement value of the dark current in patch detection ATR control (P wave / S wave)
2
P-SENS-S
Detected value of the light volume on the base (drum) in patch detection ATR control (S wave)
2
DENS-Y/M/C-H
History of the light ATR sensor measurement values (Y/M/C, last 8 values)
2
DS-S-Y/M/C/K-H
History of the patch image detection results (Y/M/C/K, last 8 values)
2
P-LED-DA
D/A setting value of LED for the patch image detection sensor
2
SPL-LG-Y/M/C
Supply history of Y/M/C color
Display the last 8 supplies.
Display range: 00 to 50 (0 to 800g)
2
COPIER>DISPLAY>DPOT
Subheading
Contents
Level