Canon imagePRESS C1 Service Manual - page 430
Manual is about: imagePRESS C1 Series
of
1265
Chapter 7
7-81
F-7-101
[1] ITB
[2] Thermal reed switch
[3] ITB heater
ITB heater control is activated by turning ON the environmental switch on the inside left side of the machine when the main switch is ON and also OFF.
F-7-102
[1] Environmental switch
Reference
The thermistor for the temperature is used. Then the temperature of ITB heater is not adjustable.
The temperature of the ITB heater cannot be checked by the service mode.
[1]
[2]
[3]
ON
ON
[1]