Canon imagePRESS C1 Service Manual - page 884
Chapter 15
15-21
T-15-5
YY
Description
Measures
*1
3
Writing
interruption (at
start-up)
1. Specify the corresponding partition number to CHK-TYPE and after executing HD-CHECK, turn OFF/ON the power.
2. Specify the corresponding partition number to CHK-TYPE and after executing HD-CLEAR, turn OFF/ON the power.
*2
1. Ask user to download the address book data via remote UI.
2. Specify the corresponding partition number to CHK-TYPE and after executing HD-CLEAR, turn OFF/ON the power.
3. Enter the download mode and execute the all format and system reinstallation via SST, and then turn OFF/ON the power.
*3
Recovery operation by Boot partition is only available by using SST in safe mode.
1. Specify CHK-TYPE=0 and execute HD-CHECK. After completion, turn OFF/ON the power.
2. Enter the download mode and execute the all format and system reinstallation via SST, and then turn OFF/ON the power.
*4
1. Specify CHK-TYPE=0 and execute HD-CHECK. After completion, turn OFF/ON the power.
2. Execute HD-CLEAR by CHK-TYPE=1,2,3,5 and turn OFF/ON the power.
*5
5
File system error
1. Specify the corresponding partition number to CHK-TYPE and after executing HD-CLEAR, turn OFF/ON the power.
2. After replacing HDD, reinstall the system.
*6
HD-CLEAR in service mode is not available (reason: to prevent to accidentally delete the information of this partition
(address book, filter information etc.)).
1. Ask user to download the address book data on remote UI.
2. Enter the download mode from service mode and execute the all format and system reinstallation via SST, and then turn
OFF/ON the power.
*7
1. Execute HD-CLEAR by CHK-TYPE=1,2,3,5 and turn OFF/ON the power.
2. After replacing HDD, reinstall the system.
*8
Recovery operation by Boot partition is only available by using SST on safe mode.
1. Start in safe mode and execute all format and reinstallation of system via SST, and then, turn OFF/ON the power.
2. After replacing HDD, reinstall the system.
*9
00
01
02
04
HDD contact
failure or system
error
1. Check the connection of communication cable and power cable of HDD
2. Start in safe mode and execute all format and reinstallation of system via SST, and then, turn OFF/ON the power.
3. After replacing HDD, reinstall the system.
*10
11
21
HDD connection
failure
1. Check the connection of communication cable and power cable of HDD
2. After replacing HDD, reinstall the system.
*11
13
25
Writing
interruption
It is highly possible that the document data on HDD such as BOX etc. is broken.
1. Specify the corresponding partition number to CHK-TYPE and after executing HD-CHECK, turn OFF/ON the power.
2. Specify the corresponding partition number to CHK-TYPE and after executing HD-CLEAR, turn OFF/ON the power.
(In case of BOOTDEV or APL_SENF, execute reformat and reinstallation of system via SST)
3. After replacing HDD, reinstall the system.
*12
10
12
14
22
23
24
System error or
packet data error
1. Start in safe mode and execute all format and reinstallation of system via SST, and then, turn OFF/ON the power.
2. After replacing HDD, reinstall the system