Canon imagePRESS C1 Service Manual - page 1119
Chapter 16
16-222
SHT-DCSW
Skip the DCON termination processing when executing shutdown.
2
Setting range
0: Execute shutdown after the DCON fan control is terminated.
1: Execute shutdown before the DCON fan control is terminated.
Standard value
0
ADJ-VPP
Adjust the developing bias Vpp.
Function to adjust Vpp for the developing AC bias.
2
Setting range
-4 to 2
Standard value
0
AST-SEL
Change the range of the advanced smoothing.
AST-SEL (AST level SELect)
2
Setting range
0 to 3
Standard value
2
REGM-SEL
Change the range of the thin line density correction.
REGM-SEL (REos GaMma SELect)
2
Setting range
0 to 4
Standard value
2
ADJ-BLNK
Adjust the length of the developing bias blank.
Function to adjust the blank length of the developing bank pulse bias
2
Setting range
1 to 4
Standard value
3
2TR-RVON
Set ON/OFF of the weak bias of the trail edge of paper.
Set this mode to ON when scattering occurred to the trail edge of the image on the 2nd side in 1/
3 speed.
2
Setting range
0: OFF
1: ON
Standard value
0
USB-RCNT
Auto-connection setting at disconnection of USB device (USB RECONNECT)
2
Setting range
0 to 1
0: Non auto-connect
1: Auto-connect
Standard value
0
COPIER>OPTION>BODY
Subheading Contents
Level