Canon imagePRESS C1 Service Manual - page 997
Chapter 16
16-100
T-16-100
14.P-PASCAL
Use it if the gradation fault is occurred after executing the printer PASCAL.
T-16-101
COPIER>ADJUST>EXP-LED
Subheading Contents
Level
CLN-EXP
Set a cleaner pre-exposure current. (image area)
Set the light volume of cleaner pre-exposure for an image area at printing.
1
Setting range
5 to 10 (Unit: 10mA)
Standard value
8
CLN-EXP2
Set the cleaner pre-exposure current. (color/paper internal)
Set the light volume of cleaner pre-exposure for color/paper interval.
1
Setting range
5 to 10 (Unit: 10mA)
Standard value
8
COPIER>ADJUST>P-PASCAL
Subheading Contents
Level
CS1OFWMY
Adjust the main unit offset of the solid white actual measurement brightness value Y for Color
Sensor 1.
1
Setting range: 0 to 1023
Standard value: 0
CS1OFWIM
Adjust the main unit offset of the solid white ideal brightness value M for Color Sensor
1
Setting range: 0 to 1023
Standard value: 0
CS1OFDMM
Adjust the main unit offset of the solid actual measurement brightness value M for Color Sensor 1.
1
Setting range: 0 to 1023
Standard value: 0
CS1OFDMY
Adjust the main unit offset of the solid actual measurement brightness value Y for Color Sensor 1.
1
Setting range: 0 to 1023
Standard value: 0
CS1OFDIM
Adjust the main unit offset of the solid ideal brightness value M for Color Sensor 1.
1
Setting range: 0 to 1023
Standard value: 0
CS1OFDIY
Adjust the main unit offset of the solid ideal brightness value Y for Color Sensor 1.
1
Setting range: 0 to 1023
Standard value: 0
CS1OFHMM
Adjust the main unit offset of the HT actual measurement brightness value M for Color Sensor 1.
1
Setting range: 0 to 1023
Standard value: 0
CS1OFHMY
Adjust the main unit offset of the HT actual measurement brightness value Y for Color Sensor 1.
1
Setting range: 0 to 1023
Standard value: 0
CS1OFHIM
Adjust the main unit offset of the HT ideal brightness value M for Color Sensor 1.
1
Setting range: 0 to 1023
Standard value: 0