Chapter 16
16-257
SCN-FLG
Select the image area flag. (for copy image)
When a scan image was not compressed to a specified compression ratio on the controller side,
image processing is performed based on the image area flag specified by this mode.
2
Setting range
0: Character
1: Dot photo image
2: Film photo
Standard value: 0
T-LW-LVL
Switch the timing to display the warning for toner level.
Switch the threshold (%) of toner level to display the message "Toner almost empty" in the control
panel. However, when you delay the timing to display the warning message, toner may suddenly
become empty before the warning is displayed.
2
Setting range: 5 to 100 (Unit: %)
Standard value: 10
The setting value becomes valid after the main power switch is turned OFF/ON.
NWERR-SW
Switch the network-related error message display.
This mode is used to inhibit the display of a network-related error message when network
connection is not actually performed in the model which includes a network board as standard
equipment.
This mode is provided for a machine which is not connected to network, such as Lawson, while
a NADA machine is connected to network as a default setting.
2
Setting range
0: Do not display the message.
1: Display the message.
Standard value: 1
FX-SPD
Make a fine adjustment of the fixing roller speed.
Make a fine adjustment of the fixing speed because the trail edge of paper contacts the ITB and it
sometimes causes a fading image when the loop between the secondary transfer roller and the
fixing roller is too large. When a fine adjustment is made to the fixing speed, the same adjustment
is made to the speed of delivery vertical path. When you increase the setting value, the speed
becomes faster.
2
Setting range: -3 to 3
Standard value: 0
The setting value becomes valid after the main power switch is turned OFF/ON.
STS-PORT
Use it to turn on/off the T.O.T (TUIF over TCP/IP) async type status communication port.
2
Turns on/off the inquiry/response (sync) type status communication port for TUF over TCP/IP.
settings
0: off (default); 1: on
For service NAVI, set the value as '1' when connecting the PC and main body by crossing cable.
MEMO:
T.O.T (TUIF over TCP/IP)
Communication protocol between embedded application presentation (UI) and applications
within the device including COPY/SEND/BOX etc., (Canon original protocol)
CMD-PORT
Use it to turn off/on the T.O.T (TUIF over TCP/IP) sync type command communication port.
2
Turns on/off the inquiry/response (sync) type command communication port for TUIF over TCP/
IP.
settings
0: off (default); 1: on
For service NAVI, set the value as '1' when connecting the PC and main body by crossing cable.
MEMO:
T.O.T (TUIF over TCP/IP)
Communication protocol between embedded application presentation (UI) and applications
within the device including COPY/SEND/BOX etc., (Canon original protocol)
MODELSZ2
Provide global measures for plate document size detection.
When 1 is set for this mode, INCH/AB (global) mode is provided regardless of the MODEL-SZ
setting, which is a flag to switch INCH or AB.
2
Settings
0: normal (Detection size for each destination) (default) ; 1: Inch/AB mix detection
- This is for individual user, not used normally.
- For different-sized originals detection (Inch/AB-configuration), original size sensor is required.
SZDT-SW
Switch the mode from the CCD size detection to the photo size detection for plate document size
detection.
2
settings
0: Size detection by CCD (Default) ; 1: Size detection by photo sensor
- This is for individual user (glare protection), not used normally.
- When the value is set as '1', original size detection at open/close of the pressure plate is not
performed. For detection of the original size (without lightning the scanning lamp), original size
sensor (photo sensor) is required.
UISW-DSP
Set 'hide' or 'not hide' of the SW to switch the display to the user screen.
Set 'hide' or 'not hide' of the SW to determine which of the normal screen or the simple screen
(Lawson type) is used.
The following types of screen are available.
- Screen that has the function similar to a standard machine
- Screen that has limited function like the screen used at Lawson
A user (a store manager) specifies 'hide' or 'not hide' of the SW to switch these screens.
2
Setting range
0: Hide
1: Do not hide
Standard value: 0
COPIER > OPTION > BODY
Subheading Contents
Level