Canon imagePRESS C1 Service Manual - page 913
Chapter 16
16-16
T-16-19
14.ENVRNT
Use it to indicate the environment log.
The machine shows a log of changes taking place as indicated by the readings of the environment sensor and the output of the fixing thermistor: machine inside
temperature in deg C, humidity in %, fixing roller surface temperature (center) in deg C.
Remarks:
The intervals at which data is colleted may be changed in the following service mode item: COPIER>OPTION>BODY>ENVP-IN.
F-16-13
T-16-20
15.HT-C
In case the hue variation occurs, check the value of this item.
Appropriate range: 100 to 600
In case the value is out of the range:
1. Execute the automatic gradation correction (either full correction or quick correction.)
2. If the value is still out of the appropriate range, replace the patch sensor.
Location code
Alarm code
02 scanner
0002
indicates the presence of dirt on the glass for stream reading.
0020
line correction alarm (upon detection of dust on the stream reading glass between originals)
04 pickup/feed
0001
0002
0003
0004
0008
cassette 1 lifter error
cassette 2 lifter error
cassette 3 lifter error
cassette 4 lifter error
optional deck lifter error
33 fan
0011
fixing heat discharge fan
50 ADF
0010
indicates that the original separation alarm condition has occurred 3 times in sequence (i.e., faulty
pickup of the 1st original).
61 finisher
0001
staple absent
62 saddle stitcher
0001
stitch staple absent
65 puncher
0001
punch waste case full
Item
Description
No.
order of data collection (highest number indicating oldest data)
DATE
date of data collection
TIME
time of data collection
D+deg C
machine inside temperature
E+%
machine inside Humidity
F+deg C
fixing roller surface (center) temperature