Canon imagePRESS C1 Service Manual - page 948
Chapter 16
16-51
P006
15
Detection of locking of the primary expiration FAN
FM1
L: Locked (synchronous rotation)
14
Detection of locking of the transfer drum cleaner cooling
FAN
FM7
L: Locked (synchronous rotation)
13
Cartridge motor error LC
M32
L: Error
12
Cartridge motor error LM
M31
L: Error
11
Cartridge motor error K
M30
L: Error
10
Cartridge motor error C
M29
L: Error
9
Cartridge motor error M
M28
L: Error
8
Cartridge motor error Y
M27
L: Error
7
-
-
-
6
-
-
-
5
Cartridge micro SW (LC)
SW12
H: Set
4
Cartridge micro SW (LM)
SW11
H: Set
3
Cartridge micro SW (K)
SW10
H: Set
2
Cartridge micro SW (C)
SW9
H: Set
1
Cartridge micro SW (M)
SW8
H: Set
0
Cartridge micro SW (Y)
SW7
H: Set
P007
15
Reverse cooling FAN half
FM20
H: Half speed on (Full speed at port6=H)
14
Reverse cooling FAN full
FM20
H: Full speed
13
Patch detection (REAR) LED on
H: On
12
-
-
-
11
ITOP remote
-
H: On
10
Patch detection (CENTER) LED on
PS3
H: On
9
Patch detection (FRONT) LED on
PS4
H: On
8
Pre-exposure LED on
LED1
H: On
7
-
-
-
6
-
-
-
5
-
-
-
4
ITB cleaning brush roller drive motor 11
M26
(port2:port3)
(0:0)=Setting 0 (Excitation off)
(0:1)=Setting 1, (1:0)=Setting 2, (1:1)=Setting 3
3
ITB cleaning brush roller drive motor 10
M26
2
ITB cleaning brush roller CW
M26
-
1
ITB cleaning brush roller MODE
M26
0: Full step (2-phase excitation)
1: Half step (1'-2-phase excitation)
0
ITB cleaning brush roller CLK
M26
Phase is switched at the edge at start-up.
P008
15
-
-
-
14
-
-
-
13
-
-
-
12
-
-
-
11
ITB cleaning brush roller detachment/attachment motor
11
M18
(port2:port3)
(0:0)=Setting 0 (Excitation off)
(0:1)=Setting 1, (1:0)=Setting 2, (1:1)=Setting 3
10
ITB cleaning brush roller detachment/attachment motor
10
M18
9
ITB cleaning brush roller detachment/attachment MODE
M18
0: Full step (2-phase excitation)
1: Half step (1'-2-phase excitation)
8
ITB cleaning brush roller detachment/attachment CLK
M18
Phase is switched at the edge at start-up.
7
-
-
-
6
-
-
-
5
-
-
-
4
-
-
-
3
-
-
-
2
-
-
-
1
Post-fixing lower FAN half
FM17
H: Half speed on (Full speed at port0=H)
0
Post-fixing lower FAN full
FM17
H: Full speed
Address
bit
Name
Symbol
Remarks