F-BLT-RT
Measure at E007 (fixing belt displacement error) occurrence
Specify the host machine operation at E007 occurrence.
1
Setting range: 0 to 1
0: Automatic restore does not take effect at power OFF/ON.
1: Automatic restore takes effect at power OFF/ON.
Standard value: 0
This item applies to the upgraded device (DCON Ver11.03 or later and Cont Ver24.04 or later).
W-CLN-P
Set the interval (number of copies) to perform automatic cleaning of the primary charging wire in
the normal environment.
The setting value becomes valid after the main power switch is turned OFF/ON.
2
Setting range: 50 to 10000 (copies)
Standard value: 2000
W-CLN-T
Set the interval (number of copies) to perform automatic cleaning of the charging wire of the pre-
transfer charging assembly.
2
Setting range: 50 to 10000 (copies)
PRI-FAN
Select the primary fan drive mode.
Prevent the half tone unevenness due to the soiled primary charging assembly grid.
2
Setting range
0: Half speed in the high temperature/humidity environment
1: Full speed mainly in the low temperature / low humidity environment.
Standard value: 0
The setting value becomes valid after the main power switch is turned OFF/ON.
SCANSLCT
Set ON/OFF of the function to calculate the scan area based on the paper size.
2
Setting range
0: OFF (Determine the scan area by document detection.)
1: ON (Determine the scan area by paper size.)
Standard value: 0
When setting as '1', if the media size is larger than the original size, productivity decreases due to
a larger scanning area.
DH-SW
Perform Dhalf correction.
2
Setting range
0: Do not perform Dhalf control.
1: Perform Dhalf control.
Standard value: 1
The setting value becomes valid after the main power switch is turned OFF/ON.
SENS-CNF
Set the display of the document detection sensor.
2
Setting range
0: AB system
1: Inch system
Standard value: 0
Due to the reader controller PCB RAM clear, the value is set as '0'. Re-define the value as '1' for
inch-configuration destination machines (North America etc.,)
DM-SW
Switching-over of the enabling / disabling of the image density correction control or image
gradation correction control.
2
Not used in this machine
Setting range
0: No implemented
1: Always implemented
2: Always implemented
3: Always implemented
4: Always implemented
Change the interval (Default: 200 copies) using COPIER/OPTION/BODY/(INTROT-1/
INTROT-2/INTROT-T).
Standard value: 3
The setting value becomes valid after the main power switch is turned OFF / ON.
RAW-DATA
Make a setting to print out the received data as it is.
When there is a problem in the received image, this mode is used to determine whether the
problem is caused by the data contents or image processing.
2
Setting range
0: Normal operation
1: Print out the received data as it is.
Standard value: 0
FDW-DLV
Select the 'face up' or 'face down' delivery when specifying multiple copies.
When multiple copies are specified, 'face up' delivery is usually performed. However, this mode
is provided to perform 'face down' delivery to guarantee stacking condition.
(However, this mode is invalid when a finisher is installed.)
2
Setting range
0: 'Face up' for all setting for one sheet of document
1: 'Face up' when specifying one copy, and 'face down' when specifying multiple copies for one
sheet of document
Standard value: 0
The setting mode becomes valid after the power switch is turned OFF/ON.
RMT-LANG
Switch the remote UI language used on Web.
Setting method
Select the language code using the +/- key.
2
IFAX-LIM
Restrict the number of lines output when receiving large volume of data by iFAX
2
Setting range
0: No restriction
0 to 999
Standard value: 500