Canon imagePRESS C1 Service Manual - page 1115
Chapter 16
16-218
CHNG-CMD
Use it to set the T.O.T (TUIF over TCP/IP) command connection port number.
2
Use it to set the port number for the command connection in an TUIF over TCP/IP environment.
This is used for changing the port No. in service NAVI.
settings
1 to 65535 (default: 20000)
MEMO:
T.O.T (TUIF over TCP/IP)
Communication protocol between embedded application presentation (UI) and applications
within the device including COPY/SEND/BOX etc., (Canon original protocol)
MEAP-DSP
Use it to prohibit a switch-over from the MEAP screen to the standard screen (COPY/SEND/BOX
screen etc.,).
2
Although setting the value as '1' in COPIER > OPTION > BODY > MEAP-DSP, at the occurrence
of error/jam/alarm, the display transits to the standard screen for showing a warning.
When setting this value as '1', at the occurrence of error/jam/alarm,
- Display transition to the standard screen is prohibited.
- Warning is displayed on the MEAP screen to urge the user to contact servicing.
settings
0: off (display warning screen; default); 1: on (do not display warning screen)
ANIM-SW
Set whether or not to use the full-screen display for jam/alarm in MEAP application operation.
2
Although setting the value as '1' in COPIER > OPTION > BODY > MEAP-DSP, at the occurrence
of error/jam/alarm, the display transits to the standard screen for showing a warning.
When setting this value as '1', at the occurrence of error/jam/alarm,
- Display transition to the standard screen is prohibited.
- Warning is displayed on the MEAP screen to urge the user to contact servicing.
settings
0: off (display warning screen; default); 1: on (do not display warning screen)
HDD-TMP
Set a temperature for judgment of an abnormal status with low temperature in SAMSUNG HDD.
2
Setting range
0 to 30 (deg C)
Standard value
2
The setting value becomes valid after the main power switch is turned OFF/ON.
HDD-TIM
Set the grace time until it is judged as an abnormal status with low temperature in SAMSUNG
HDD.
2
Setting range
0 to 200 (minute)
Standard value
10
The setting value becomes valid after the main power switch is turned OFF/ON.
HDD-SW
Set whether or not to display the E code for an abnormal status with low temperature in
SAMSUNG HDD.
2
Setting range
0: Do not display the code.
1: Display the code.
Standard value
0
The setting value becomes valid after the main power switch is turned OFF/ON.
COPIER>OPTION>BODY
Subheading Contents
Level