3Com S7902E Command Reference Manual - page 1155
1-31
Parameters
interval
: IGMP query interval in seconds, namely interval between IGMP general queries, with an
effective range of 1 to 18,000.
Description
Use the
timer query
command to configure the IGMP query interval globally.
Use the
undo timer query
command to restore the default setting.
By default, IGMP query interval is 60 seconds.
Related commands:
igmp timer query
,
timer other-querier-present
,
display igmp interface
.
Examples
# Set the IGMP query interval to 125 seconds globally in the public instance.
[Sysname] igmp
[Sysname-igmp] timer query 125
version (IGMP view)
Syntax
version version-number
undo version
View
Public instance IGMP view, VPN instance IGMP view
Default Level
2: System level
Parameters
version-number
: IGMP version, in the range of 1 to 3.
Description
Use the
version
command to configure the IGMP version globally.
Use the
undo version
command to restore the system default.
The default IGMP version is version 2.
Related commands:
igmp version
.
Examples
# Set the global IGMP version to IGMPv1 in the public instance.
[Sysname] igmp
[Sysname-igmp] version 1