[Sysname-nqa-admin-test] type dhcp
[Syaname-nqa-admin-test-dhcp] probe timeout 10000
reaction
Syntax
reaction
item-num
checked-element probe-fail threshold-type consecutive occurrences
[
action-type
{
none
|
trigger-only
} ]
undo reaction
item-num
View
DHCP, DLSw, FTP, HTTP, ICMP-echo, SNMP, TCP, UDP-echo test type view
Default Level
2: System level
Parameters
item-num
: Number of the reaction entry, in the range 1 to 10.
checked-element
: Type of the monitored element in collaboration. At present, the type of the
monitored element can be probe failure only.
probe-fail
: The type of the monitored element is probe failure.
threshold-type consecutive
: Threshold type is consecutive probe failures.
occurrences
: Number of consecutive probe failures, in the range 1 to 16.
action-type
: Triggered action type, defaulting to
none
.
none
: No actions.
trigger-only
: Triggers collaboration between other modules only.
Description
Use the
reaction
command to establish a collaboration entry to monitor the probe results of the current
test group. If the number of consecutive probe failures reaches the threshold, collaboration with other
modules is triggered.
Use the
undo reaction
command to remove the collaboration entry.
By default, no collaboration entries are configured.
Note that you cannot modify the content of a collaboration object using the
reaction
command after the
collaboration object is created.
Related commands:
track
in the
Track Commands
in the
System Volume
.
Examples
# Create collaboration object 1. If the number of consecutive probe failures reaches 3, collaboration
with other modules is triggered.
[Sysname] nqa entry admin test
[Sysname-nqa-admin-test] type tcp