3Com S7902E Command Reference Manual - page 338
1-28
using onu
Syntax
using onu
{
onu-number1
[
to
onu-number2
] }
&
undo using onu
{
onu-number1
[
to
onu-number2
] }
&
View
OLT port view
Default Level
2: System level
Parameters
onu-number1
: ONU port number, in the range 1 to 64.
to
onu-number2
: Specifies an ONU port range.
onu-number2
is an ONU port number, in the range 1 to
64.
&
: Indicates that you can specify up to 10 ONU port numbers/port ranges.
Description
Use the
using onu
command to create virtual ONU port(s) for the current OLT port.
Use the
undo using onu
command to remove the specified ONU port(s) under the current OLT port.
By default, no ONU port is created for any OLT port when the EPON card is started up.
To use the
interface
command to enter ONU port view, use the
using onu
command to create the
corresponding ONU port first.
Examples
# Create ONU 3/0/1:5 whose sub-channel number is 5 for OLT 3/0/1.
[Sysname] interface olt 3/0/1
[Sysname-Olt3/0/1] using onu 5
Please wait…Done.
# Create ONU ports whose sub-channel numbers are 1 to 5 for OLT 3/0/1.
[Sysname] interface olt 3/0/1
[Sysname-Olt3/0/1] using onu 1 to 5
Please wait….Done.
[Sysname-Olt3/0/1] display brief interface onu
The brief information of interface(s) under bridge mode:
Interface Link Speed Duplex Link-type PVID
Onu3/0/1:1 DOWN -- -- access 1
Onu3/0/1:2 DOWN -- -- access 1
Onu3/0/1:3 DOWN -- -- access 1
Onu3/0/1:4 DOWN -- -- access 1
Onu3/0/1:5 DOWN -- -- access 1