3Com S7902E Command Reference Manual - page 281
1-14
Use the
undo oam errored-frame-seconds period
command to restore the default.
By default, the errored frame seconds detection interval is 60 seconds.
A errored frame seconds event occurs when a errored frame seconds detection interval expires and the
number of the error seconds of an Ethernet port is larger than (or equal to) the errored frame seconds
event triggering threshold. (A second is called an error second if error frames occur in the second.)
The errored frame seconds detection interval configured applies to all the Ethernet ports on which
Ethernet OAM connections are established.
Related commands:
oam
errored-frame-seconds threshold
,
display oam link-event
,
display oam
configuration
.
Examples
# Set the errored frame seconds detection interval to 100 seconds.
[Sysname] oam errored-frame-seconds period 100
oam errored-frame-seconds threshold
Syntax
oam errored-frame-seconds threshold threshold-value
undo oam errored-frame-seconds threshold
View
System view
Default Level
2: System level
Parameters
threshold-value
: Errored frame seconds event triggering threshold, ranging from 0 to 900.
Description
Use the
oam errored-frame-seconds threshold
command to set the errored frame seconds event
triggering threshold.
Use the
undo oam errored-frame-seconds threshold
command to restore the default.
By default, the errored frame seconds event triggering threshold is 1.
A errored frame seconds event occurs when a errored frame seconds detection interval expires and the
number of the error seconds of an Ethernet port is larger than (or equal to) the errored frame seconds
event triggering threshold. (A second is called an error second if error frames occur in the second.)
The errored frame seconds event triggering threshold configured applies to all the Ethernet ports on
which Ethernet OAM connections are established.
Related commands:
oam
errored-frame-seconds period
,
display oam link-event
,
display oam
configuration
.
Examples
# Set the errored frame seconds event triggering threshold to 100.