3Com S7902E Command Reference Manual - page 2185
1-12
Parameters
None
Description
Use the
info-center enable
command to enable information center.
Use the
undo info-center enable
command to disable the information center.
The system outputs information to the log host or the console only after the information center is
enabled first.
By default, the information center is enabled.
Examples
# Enable the information center.
[Sysname] info-center enable
% Information center is enabled
info-center logbuffer
Syntax
info-center logbuffer
[
channel
{
channel
-
number | channel
-
name
}
|
size buffersize
] *
undo info-center logbuffer
[
channel
|
size
]
View
System view
Default Level
2: System level
Parameters
channel
-
number
: A specified channel number, in the range 0 to 9.
channel
-
name
: Specifies a channel name, which could be a default name or a self-defined name. The
user needs to specify a channel name first before using it as a self-defined channel name. For more
information, refer to the
info-center channel name
command.
buffersize
: Specifies the maximum number of log messages that can be stored in a log buffer, in the
range 0 to 1,024 with 512 as the default value.
Description
Use the
info-center logbuffer
command to enable information output to a log buffer and set the
corresponding parameters.
Use the
undo info-center logbuffer
command to disable information output to a log buffer.
By default, information is output to the log buffer with the default channel of channel 4 (logbuffer) and
the default buffer size of 512.
Note that the
info-center logbuffer
command takes effect only after the information center is enabled
with the
info-center enable
command.