3Com S7902E Command Reference Manual - page 397
3-14
The system generates an error frame seconds summary alarm when the number of error frame
seconds (in an error frame second, at least one error frame occurs) in a specific time period (for
example, 1 minute) exceeds the corresponding predefined threshold.
Related commands:
alarm oam error-frame-seconds-summary enable
.
The commands here take effect only for OAM 2.0 and above.
Examples
# Set the window size and alarm threshold for error frame seconds summary to 800 and 2 on ONU
1/0/1:1.
[Sysname] interface onu 1/0/1:1
[Sysname-Onu1/0/1:1] alarm oam error-frame-seconds-summary window 800 threshold 2
alarm oam error-frame-seconds-summary enable
Syntax
alarm oam error-frame-seconds-summary enable
undo alarm oam error-frame-seconds-summary enable
View
OLT port view, ONU port view, FTTH view
Default Level
2: System level
Parameters
None
Description
Use the
alarm oam error-frame-seconds-summary enable
command to enable the error frame
seconds summary alarm.
Use the
undo alarm oam error-frame-seconds-summary enable
command to disable the error
frame seconds summary alarm.
By default, the error frame seconds summary alarm is enabled.