3Com S7902E Command Reference Manual - page 402
3-19
Examples
# Enable the remote stable alarm on OLT 3/0/1.
[Sysname] interface olt 3/0/1
[Sysname-Olt3/0/1] alarm remote-stable enable
alarm software-error enable
Syntax
alarm software-error enable
undo alarm software-error enable
View
FTTH view
Default Level
2: System level
Parameters
None
Description
Use the
alarm software-error enable
command to enable the software error alarm of the system.
Use the
undo alarm software-error enable
command to disable the software error alarm of the
system.
The system generates a software error alarm when a signal error, DA abnormity (that is, data access
abnormity) error, or memory allocation failure occurs.
By default, the software error alarm is enabled.
Examples
# Enable the software error alarm in the EPON system.
[Sysname] ftth
[Sysname-ftth] alarm software-error enable
monitor enable
Syntax
monitor enable
undo
monitor enable
View
FTTH view