3Com S7902E Command Reference Manual - page 2220
1-17
View
Any view
Default Level
1: Monitor level
Parameters
None
Description
Use the
display poe-power dc-output state
command to display the state information of the DC
output power
Examples
# Display the state information of the DC output power.
DC Output State : Normal
Table 1-12
display poe-power dc-output state command output description
Field
Description
DC Output State
DC output state. See
Table 1-10
.
display poe-power dc-output value
Syntax
display poe-power dc-output value
View
Any view
Default Level
1: Monitor level
Parameters
None
Description
Use the
display poe-power dc-output value
command to display the parameter values of the DC
output power.
Examples
# Display the parameter values of the DC output power.
DC Output Voltage : 54.05 V
DC Output Current : 0.35 A