3Com S7902E Command Reference Manual - Alarm Configuration Commands
3-1
3
Alarm Configuration Commands
An alarm command executed in FTTH view will take effect on all the OLT ports of the system or all
the ONUs under the OLT;
An alarm command executed in OLT port view will take effect on the current port and all the ONUs
under it;
An alarm command executed in ONU port view will take effect only on the ONUs under the port.
Alarm Configuration Commands
alarm bit-error-rate
Syntax
alarm bit-error-rate
{
direction
{
uplink
|
downlink
|
up-down-link
} |
threshold threshold
}
*
undo alarm bit-error-rate
{
direction
|
threshold
}
*
View
OLT port view, FTTH view
Default Level
2: System level
Parameters
uplink
: Specifies the monitor direction. Only uplink data will be monitored.
downlink
: Specifies the monitor direction. Only downlink data will be monitored.
up-down-link
: Specifies the monitor direction. Both uplink and downlink data between OLT and ONU
will be monitored.
threshold threshold
: Specifies the alarm threshold of bit error rate. The
threshold
argument ranges
from 1 to 10
9
and defaults to 10 (in 10
-9
).
Description
Use the
alarm bit-error-rate
command to configure the monitor direction and the alarm threshold of the
bit error rate.
Use the
undo alarm bit-error-rate
command to restore the default monitor direction and alarm
threshold.