1-15
View
Ethernet interface view
Default Level
2: System level
Parameters
None
Description
Use the
flow-control
command to enable flow control on an Ethernet interface.
Use the
undo flow-control
command to disable flow control on an Ethernet interface.
By default, flow control on an Ethernet interface is disabled.
The flow control function takes effect on the local Ethernet interface only when it is enabled on both the
local and peer devices.
Examples
# Enable flow control on interface Ethernet 2/0/1.
[Sysname] interface ethernet 2/0/1
[Sysname-Ethernet2/0/1] flow-control
flow-interval
Syntax
flow-interval interval
undo flow-interval
View
Layer 2 Ethernet interface view
Default Level
2: System level
Parameters
interval
: Time interval at which interface statistics are collected, in the range of 5 to 300 seconds, a
multiple of 5. The default value is 300 seconds.
Description
Use the
flow-interval
command to configure the time interval for collecting interface statistics.