3Com S7902E Command Reference Manual - page 1486
1-16
Parameters
interval
: MLD last listener query interval in units of seconds, namely the length of time the device waits
between sending IGMP multicast-address-specific queries. The effective range is 1 to 5.
Description
Use the
mld-snooping last-listener-query-interval
command to configure the MLD last-listener query
interval in the VLAN.
Use the
undo mld-snooping last-listener-query-interval
command to restore the system default.
By default, the MLD last listener query interval is 1 second.
This command takes effect only if MLD Snooping is enabled in the VLAN.
Related commands:
last-listener-query-interval
.
Examples
# Set the MLD last-listener query interval to 3 seconds in VLAN 2.
[Sysname] vlan 2
[Sysname-vlan2] mld-snooping last-listener-query-interval 3
mld-snooping max-response-time
Syntax
mld-snooping max-response-time interval
undo mld-snooping max-response-time
View
VLAN view
Default Level
2: System level
Parameters
interval
: Maximum response time for MLD general queries, in units of seconds. The effective range is 1
to 25.
Description
Use the
mld-snooping max-response-time
command to configure the maximum response time for
MLD general queries in the VLAN.
Use the
undo mld-snooping max-response-time
command to restore the default setting.
By default, the maximum response time for MLD general queries is 10 seconds.
This command takes effect only if MLD Snooping is enabled in the VLAN.
Related commands:
max-response-time
,
mld-snooping query-interval
.
Examples
# Set the maximum response time for MLD general queries to 5 seconds in VLAN 2.