3Com S7902E Command Reference Manual - page 354
2-16
vlan-id value
: Specifies the VLAN ID of test frames. The
value
argument ranges from 1 to 4094 and
defaults to 1.
Description
Use the
linktest
command to test the connectivity of the optical link between the OLT and the ONU.
Make sure the ONU is online before you perform the link connectivity test.
Examples
# Set the number of test frames to 100 to test the link between the OLT and ONU 3/0/1:1.
[Sysname] interface onu 3/0/1:1
[Sysname-Onu3/0/1:1] linktest frame-number 100
It may affect data transmission, continue?[Y/N]:y
Maximum delay(in TQ): 26408
Mean delay(in TQ) : 24777
Minimum delay(in TQ): 19922
Sent frames : 100
Received frames : 100
Error frames : 0
If
The link is disconnected!
is displayed, it means that the ONU sent some frames successfully but no
correct frames are received, namely, the value of the
Received frames
field is 0.
loopback enable
Syntax
loopback
enable
undo loopback enable
View
ONU port view
Default Level
2: System level
Parameters
None
Description
Use the
loopback enable
command to enable MAC loopback for the ONU.
Use the
undo loopback
enable
command to cancel loopback.