3Com S7902E Command Reference Manual - page 1557
1-25
Description
Use the
du-readvertise timer
command to set the interval for label readvertisement in DU mode.
Use the
undo du-readvertise timer
command to restore the default.
By default, the interval for label readvertisement in DU mode is 30 seconds.
Examples
# Set the DU mode label readvertisement interval to 100 seconds for the public network LDP instance.
[Sysname] mpls ldp
[Sysname-mpls-ldp] du-readvertise timer 100
# Set the DU mode label readvertisement interval to 100 seconds for LDP instance
vpn1
.
[Sysname] mpls ldp vpn-instance vpn1
[Sysname-mpls-ldp-vpn-instance-vpn1] du-readvertise timer 100
graceful-restart (MPLS LDP view)
Syntax
graceful-restart
undo graceful-restart
View
MPLS LDP view
Default Level
1: Monitor level
Parameters
None
Description
Use the
graceful-restart
command to enable MPLS LDP Graceful Restart (GR).
Use the
undo graceful-restart
command to disable MPLS LDP GR.
By default, MPLS LDP GR is disabled.
Note that enabling or disabling GR will cause all LDP sessions and all LSPs based on the sessions to
be removed and then reestablished.
Examples
# Enable MPLS LDP GR.
[Sysname] mpls lsr-id 1.1.1.1
[Sysname] mpls
[Sysname-mpls] quit
[Sysname] mpls ldp
[Sysname-mpls-ldp] graceful-restart