3Com S7902E Command Reference Manual - page 222
1-30
View
VLAN view
Default Level
2: System level
Parameters
ip-subnet-index
: Beginning IP subnet Index, in the range of 0 to 11. This value can be configured by
users, or automatically numbered by system based on the order in which the IP subnets or IP addresses
are associated with the VLAN.
ip
ip-address
[
mask
]: Specifies the source IP address or network address based on which the
subnet-based VLANs are classified, in dotted decimal notation. The
mask
argument is the subnet mask
of the source IP address or network address, in dotted decimal notation with a default value of
255.255.255.0.
to
: Specifies an IP subnet index range.
ip-subnet-end
: End IP subnet index, in the range of 0 to 11. This argument must be greater than or equal
to the beginning IP subnet index.
all
: Removes all the associations between VLANs and IP subnets or IP addresses.
Description
Use the
ip-subnet-vlan
command to associate the current VLAN with a specified IP subnet or IP
address.
Use the
undo ip-subnet-vlan
command to remove the association.
Note that the IP subnet or IP address cannot be a multicast network segment or a multicast address.
Related commands:
display ip-subnet-vlan vlan
.
Examples
# Configure VLAN 3 as an IP subnet-based VLAN and associate it with the 192.168.1.0/24 network
segment.
[Sysname] vlan 3
[Sysname-vlan3] ip-subnet-vlan ip 192.168.1.0 255.255.255.0
port hybrid ip-subnet-vlan vlan
Syntax
port hybrid ip-subnet-vlan
vlan
vlan-id
undo
port hybrid ip-subnet-vlan
{
vlan
vlan-id
|
all
}
View
Ethernet interface view, port group view, Layer-2 aggregate interface view
Default Level
2: System level