3Com S7902E Command Reference Manual - page 2031
1-17
Field
Description
RX power low
Incoming (RX) power level is low.
display transceiver diagnosis
Syntax
display transceiver diagnosis interface
[
interface-type interface-number
]
View
Any view
Default Level
2: System level
Parameters
interface
[
interface-type interface-number
]: Displays the currently measured value of digital diagnosis
parameters of the H3C customized anti-spoofing pluggable optical transceiver plugged in the specified
interface.
interface-type interface-number
represents interface type and interface number. If it is not
specified, the command displays the currently measured value of digital diagnosis parameters of H3C
customized anti-spoofing pluggable optical transceivers in all the interfaces.
Description
Use the
display transceiver diagnosis
command to display the currently measured value of digital
diagnosis parameters of H3C customized anti-spoofing pluggable optical transceivers.
Examples
# Display the currently measured value of the digital diagnosis parameters of the H3C customized
anti-spoofing pluggable optical transceiver plugged in interface GigabitEthernet 2/0/2.
GigabitEthernet2/0/2 transceiver diagnostic information:
Current diagnostic parameters:
Temp(°C) Voltage(V) Bias(mA) RX power(dBM) TX power(dBM)
36 3.31 6.13 -35.64 -5.19
Table 1-7
display transceiver diagnosis command output description
Field
Description
transceiver diagnostic information
Digital diagnosis information of the transceiver
plugged in the interface
Current diagnostic parameters
Current diagnostic parameters
Temp.(°C)
Digital diagnosis parameter-temperature, in °C,
with the precision to 1°C.
Voltage(V)
Digital diagnosis parameter-voltage, in V, with the
precision to 0.01 V.
Bias(mA)
Digital diagnosis parameter-bias current, in mA,
with the precision to 0.01 mA.