3Com S7902E Command Reference Manual - page 273
1-6
Parameters
None
Description
Use the
display oam configuration
command to display global Ethernet OAM configuration, including
the periods and thresholds for Ethernet OAM link error event detection.
Related commands:
oam
errored-frame period
,
oam
errored-frame threshold
,
oam
errored-frame-period period
,
oam
errored-frame-period threshold
,
oam
errored-frame-seconds
period
,
oam
errored-frame-seconds threshold
.
Examples
# Display global Ethernet OAM configuration.
Configuration of the link event window/threshold :
--------------------------------------------------------------------------
Errored-symbol Event period(in seconds) : 1
Errored-symbol Event threshold : 1
Errored-frame Event period(in seconds) : 1
Errored-frame Event threshold : 1
Errored-frame-period Event period(in ms) : 1000
Errored-frame-period Event threshold : 1
Errored-frame-seconds Event period(in seconds) : 60
Errored-frame-seconds Event threshold : 1
Table 1-5 display oam configuration
command output description
Field
Description
Configuration of the link event window/threshold
Detection intervals and triggering thresholds
configured for link events
Errored-symbol Event period (in seconds)
Errored symbol detection interval, which defaults
to one second.
Errored-symbol Event threshold
Errored symbol event triggering threshold, which
defaults to 1.
Errored-frame Event period (in seconds)
Errored frame detection interval, which defaults
to one second.
Errored-frame Event threshold
Errored frame event triggering threshold, which
defaults to 1.
Errored-frame-period Event period (in ms)
Errored frame period detection interval, which
defaults to 1000 milliseconds.
Errored-frame-period Event threshold
Errored frame period event triggering threshold,
which defaults to 1.
Errored-frame-seconds Event period (in
seconds)
Errored frame seconds detection interval, which
defaults to 60 seconds.
Errored-frame-seconds Event threshold
Errored frame seconds event triggering
threshold, which defaults to 1.