3Com S7902E Command Reference Manual - page 280
1-13
View
System view
Default Level
2: System level
Parameters
threshold-value
: Errored frame period event triggering threshold, ranging from 0 to 4294967295.
Description
Use the
oam errored-frame-period threshold
command to set the errored frame period event
triggering threshold.
Use the
undo oam errored-frame-period threshold
command to restore the default.
By default, the errored frame period event triggering threshold is 1.
A errored frame period event occurs when a errored frame period detection interval expires and the
number of the frame errors occurred on an Ethernet port is larger than (or equal to) the errored frame
period event triggering threshold.
The errored frame period event triggering threshold configured applies to all the Ethernet ports on which
OAM connections are established.
Related commands:
oam
errored-frame-period period
,
display oam link-event
,
display oam
configuration
.
Examples
# Set the errored frame period event triggering threshold to 100.
[Sysname] oam errored-frame-period threshold 100
oam errored-frame-seconds period
Syntax
oam errored-frame-seconds period period-value
undo oam errored-frame-seconds period
View
System view
Default Level
2: System level
Parameters
period-value
: Errored frame seconds detection interval, ranging from 10 to 900 (in seconds).
Description
Use the
oam errored-frame-seconds period
command to set the errored frame seconds detection
interval.