3Com S7902E Command Reference Manual - page 396
3-13
Parameters
None
Description
Use the
alarm oam error-frame enable
command to enable the error frame alarm.
Use the
undo alarm oam error-frame enable
command to disable the error frame alarm.
By default, this function is enabled.
The commands here take effect only for OAM 2.0 and above.
Examples
# Enable the error frame alarm for the ONU corresponding to ONU 3/0/1:1.
[Sysname] interface onu 3/0/1:1
[Sysname-Onu3/0/1:1] alarm oam error-frame enable
alarm oam error-frame-seconds-summary
Syntax
alarm oam error-frame-seconds-summary
{
window window
|
threshold threshold
}
*
undo alarm oam error-frame-seconds-summary
{
window
|
threshold
}
*
View
OLT port view, ONU port view, FTTH view
Default Level
2: System level
Parameters
window window
: Specifies the window size, in the range 100 to 9000 (in 100 ms). By default, the
window size is 600.
threshold threshold
: Specifies the alarm threshold, in the range 1 to 900 (in seconds). By default, the
threshold is 1 second.
Description
Use the
alarm oam error-frame-seconds-summary
command to configure the corresponding
window size and alarm threshold.
Use the
undo
alarm oam error-frame-seconds-summary
to restore the default window size and
alarm threshold.