3Com S7902E Command Reference Manual - page 1478
1-8
Use the
undo max-response-time
command to restore the system default.
By default, the maximum response time for MLD general queries is 10 seconds.
This command works only on MLD Snooping–enabled VLANs, but not on VLANs with MLD enabled on
their VLAN interfaces.
Related commands:
mld-snooping max-response-time
,
mld-snooping query-interval
.
Examples
# Set the maximum response time for MLD general queries globally to 5 seconds.
[Sysname] mld-snooping
[Sysname-mld-snooping] max-response-time 5
mld-snooping
Syntax
mld-snooping
undo mld-snooping
View
System view
Default Level
2: System level
Parameters
None
Description
Use the
mld-snooping
command to enable MLD Snooping globally and enter MLD-Snooping view.
Use the
undo mld-snooping
command to disable MLD Snooping globally.
By default, MLD Snooping is disabled.
Related commands:
mld-snooping enable
.
Examples
# Enable MLD Snooping globally and enter MLD-Snooping view.
[Sysname] mld-snooping
[Sysname-mld-snooping]
mld-snooping drop-unknown
Syntax
mld-snooping drop-unknown
undo mld-snooping drop-unknown