3Com S7902E Command Reference Manual - page 2238
1-35
poe-power output-threshold
Syntax
poe-power output-threshold
{
lower
|
upper
}
value
undo poe-power output-threshold
{
lower
|
upper
}
View
System view
Default Level
2: System level
Parameters
lower value
: Specifies an under-voltage threshold in volts. The under-voltage threshold range, default
under-voltage threshold, and recommended under-voltage threshold vary with devices.
upper value
: Specifies an over-voltage threshold in volts. The over-voltage threshold range, default
over-voltage threshold, and recommended over-voltage threshold vary with devices.
Description
Use the
poe-power output-threshold
command to configure a DC output under-voltage/over-voltage
threshold.
Use the
undo poe-power output-threshold
command to restore the default.
The default DC output under-voltage/over-voltage threshold varies with devices.
Examples
# Set a DC output under-voltage threshold to 45 V.
[Sysname] poe-power output-threshold lower 45
# Set a DC output over-voltage threshold to 57 V.
[Sysname] poe-power output-threshold upper 57
poe-profile
Syntax
poe-profile
profile-name
[
index
]
undo poe-profile
{
index index
|
name profile-name
}
View
System view
Default Level
2: System level