3Com S7902E Command Reference Manual - page 1558
1-26
graceful-restart mpls ldp
Syntax
graceful-restart mpls ldp
View
User view
Default Level
2: System level
Parameters
None
Description
Use the
graceful-restart mpls ldp
command to restart MPLS LDP gracefully.
Note that:
z
This command is used to test MPLS LDP GR without main/backup switchover. It is not
recommended in normal cases.
z
The MPLS LDP GR capability is required for this command to take effect.
Related commands:
graceful-restart
(MPLS LDP view).
Examples
# Restart MPLS LDP gracefully.
graceful-restart timer neighbor-liveness
Syntax
graceful-restart timer neighbor-liveness
timer
undo graceful-restart timer neighbor-liveness
View
MPLS LDP view
Default Level
1: Monitor level
Parameters
timer
: LDP neighbor liveness time, in the range 60 to 300 seconds.
Description
Use the
graceful-restart timer neighbor-liveness
command to set the LDP neighbor liveness time.
Use the
undo graceful-restart timer neighbor-liveness
command to restore the default.
By default, the LDP neighbor liveness time is 120 seconds.