3Com S7902E Command Reference Manual - page 388
3-5
Default Level
2: System level
Parameters
None
Description
Use the
alarm llid-mismatch enable
command to enable the LLID mismatch frame alarm.
Use the
undo alarm llid-mismatch enable
command to disable the LLID mismatch frame alarm.
By default, the LLID mismatch frame alarm is disabled.
Examples
# Enable the LLID mismatch frame alarm on OLT 3/0/1.
[Sysname] interface olt 3/0/1
[Sysname-Olt3/0/1] alarm llid-mismatch enable
alarm llid-mismatch threshold
Syntax
alarm llid-mismatch threshold threshold
undo alarm llid-mismatch threshold
View
OLT port view, FTTH view
Default Level
2: System level
Parameters
threshold threshold
: Specifies the alarm threshold of the LLID mismatch frame alarm. It ranges from
1000 to 10
9
frames and defaults to 5000 frames.
Description
Use the
alarm llid-mismatch threshold
command to configure the alarm threshold of LLID mismatch
frame.
Use the
undo alarm llid-mismatch threshold
command to restore the default alarm threshold.
The system generates an LLID mismatch frame alarm when the timeslots are used in disorder, that is,
one ONU uses another ONU's timeslot to forward data.
Related commands:
alarm llid-mismatch enable
.
Examples
# Set the alarm threshold of LLID mismatch frame to 6000 frames.
[Sysname] interface olt 1/0/1